ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 83AK122002
Layer Natural Key: 83P04243
Horizon: Bs   14.0-25.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.04380.5713-2.32760.1925
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% vol% wt% wt% wt% wtg/cc
05.4433.058.38.70.61

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.41    
<2 mm air-dry     0.11
<2 mm field moist      0.20
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 83AK122002
Layer Natural Key: 83P04244
Horizon: Bw   25.0-42.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.05240.5392-2.53400.2377
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% vol% wt% wt% wt% wtg/cc
03.4234.555.010.50.76

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.42    
<2 mm air-dry     0.11
<2 mm field moist      0.19
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 83AK122002
Layer Natural Key: 83P04245
Horizon: C   42.0-76.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.06240.4512-2.78550.2975
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% vol% wt% wt% wt% wtg/cc
01.1138.254.17.71.21

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.39    
<2 mm air-dry     0.12
<2 mm field moist      0.15
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 83AK122002
Layer Natural Key: 83P04246
Horizon: 2C   92.0-140.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.04540.4237-2.43660.2073
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% vol% wt% wt% wt% wtg/cc
00.2352.942.05.11.28

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.34    
<2 mm air-dry     0.12
<2 mm field moist      0.15
 

Soil Water Retention Curve




*Rosetta Reference NSSC SSL Report Creation