*** Taxonomy Characterization Data ***
Pedon ID: 86AZ019002( Pima, Arizona )Print Date: Nov 21 2024 1:10PM

Sampled as on Apr 1, 1986:Valencia ; Coarse-loamy, mixed, hyperthermic Fluventic Camborthid
Revised to correlated:Valencia ; Coarse-loamy, mixed, superactive, hyperthermic Fluventic Camborthids
United States Department of Agriculture
SSL-ProjectCP86AZ174   NAVAJO COUNTYNatural Resources Conservation Service
-Site IDS1986AZ019002   Lat: 32° 27' 38.00" north  Long: 112° 0' 49.99" westNational Soil Survey Center
-Pedon No. 86P0560Soil Survey Laboratory
-General Methods 1B1A, 2A1, 2BLincoln, Nebraska 68508-3866

Taxonomy Tier 1-1--2--3--4--5--6--7--8--9--10-
 
FineCaCO31500.1-75BulkColeVolResist
ClayClayClaykPaClaymmDenWhole% ofMin
Depth<.002<.0002<.002/ClayEstFrac33 kPaSoilWhole%
Layer(cm)HorzPrep(---------% of <2 mm-------)(-------- % --------)g cm-3cm cm-1
3A1a1a3A1a1a8D14A1d
 
86P032310-3C1S9.90.59351.610.010tr
86P032323-25C2S8.80.51481.66--1
86P0323325-41Bw1S11.00.48605
86P0323441-64Bw2S11.60.46631.710.0057
86P0323564-892Btkn1S24.84.30.43412
86P0323689-1192Btkn2S22.23.40.45361.670.0285
86P03237119-1522Btkn3S17.52.60.49395

Taxonomy Tier 2-1--2--3--4--5--6--7--8--9--10--11--12--13--14--15--16-
 
pHpHOrgTotAl+½ FeCO3 as(--- Base Sat ---)NZECECCEC7ECECAl
DepthH2ONaFCCOxalODOECaCO3NH4BasesP Retcmol(+)/Clay/ClaySatE CESP
Layer(cm)HorzPrep(------------------------------------------ % --------------------------------------------)kg -1%dS m-1%
4C1a2a6A1c6E1g5C15C38D18A3a5D2
 
86P032310-3C1S8.30.511100*1001.170.832
86P032323-25C2S8.60.171100*1000.942
86P0323325-41Bw1S8.60.182100*1000.787
86P0323441-64Bw2S9.00.142100*1000.710.7014
86P0323564-892Btkn1S9.00.1312100*1000.461.5234
86P0323689-1192Btkn2S8.80.1111100*1000.483.2648
86P03237119-1522Btkn3S8.70.1011100*1000.494.7055

*Extractable Ca may contain Ca from calcium carbonate or gypsum.



Pedon Calculations
Calculation NameResultUnits of Measure
 
CEC Activity, CEC7/Clay, Weighted Average0.65(NA)
Clay, carbonate free, Weighted Average15% wt
Weighted Particles, 0.1-75mm, 75 mm Base51% wt
Volume, >2mm, Weighted Average5% vol
Clay, total, Weighted Average17% wt
 
Weighted averages based on control section: 25-100 cm
NSSC SSL Report Creation