ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 88ME003001
Layer Natural Key: 88P03856
Horizon: Ap2   11.0-24.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.04490.4301-2.48790.2233
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% vol% wt% wt% wt% wtg/cc
221.8045.142.812.11.24

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.33    
<2 mm air-dry     0.11
<2 mm field moist      0.12
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 88ME003001
Layer Natural Key: 88P03857
Horizon: Bs   24.0-39.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.04340.3855-2.38660.1948
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% vol% wt% wt% wt% wtg/cc
380.9343.244.512.31.47

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.30    
<2 mm air-dry     0.11
<2 mm field moist      0.17
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 88ME003001
Layer Natural Key: 88P03858
Horizon: C1   39.0-66.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.07050.3146-1.31560.0948
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% vol% wt% wt% wt% wtg/cc
90.1641.844.913.31.81

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.25    
<2 mm air-dry     0.19
<2 mm field moist      0.09
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 88ME003001
Layer Natural Key: 88P03860
Horizon: C3   104.0-143.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.05890.3798-1.84710.0952
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% vol% wt% wt% wt% wtg/cc
350.2431.645.223.21.63

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.31    
<2 mm air-dry     0.20
<2 mm field moist      0.27
 

Soil Water Retention Curve




*Rosetta Reference NSSC SSL Report Creation