ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 91OK109003
Layer Natural Key: 91P05505
Horizon: A1   0.0-14.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.04490.4094-2.30650.1848
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 2.4645.139.415.51.37

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.31    
<2 mm air-dry     0.12
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 91OK109003
Layer Natural Key: 91P05506
Horizon: A2   14.0-30.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.04200.3941-2.09640.1557
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 1.2646.536.017.51.44

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.28    
<2 mm air-dry     0.12
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 91OK109003
Layer Natural Key: 91P05507
Horizon: BA   30.0-48.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.04950.4061-2.02330.1420
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 1.0943.836.419.81.43

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.29    
<2 mm air-dry     0.14
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 91OK109003
Layer Natural Key: 91P05508
Horizon: Bt1   48.0-78.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.06960.4048-1.60650.1028
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 0.7141.030.428.61.51

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.29    
<2 mm air-dry     0.18
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 91OK109003
Layer Natural Key: 91P05509
Horizon: Bt2   78.0-100.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.06430.3661-1.52320.0922
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 0.3653.220.026.81.67

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.27    
<2 mm air-dry     0.19
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 91OK109003
Layer Natural Key: 91P05510
Horizon: Bt3   100.0-120.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.05820.3477-1.48560.1004
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 0.2059.117.823.11.72

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.24    
<2 mm air-dry     0.16
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 91OK109003
Layer Natural Key: 91P05511
Horizon: Bt4   120.0-140.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.05790.3542-1.51290.0973
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 0.1463.113.723.21.71

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.25    
<2 mm air-dry     0.17
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 91OK109003
Layer Natural Key: 91P05512
Horizon: BC   140.0-150.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.05580.3572-1.48620.1040
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 0.0973.75.021.31.71

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.24    
<2 mm air-dry     0.16
 

Soil Water Retention Curve