ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 92KS079006
Layer Natural Key: 92P03164
Horizon: Ap1   0.0-12.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.06560.4148-1.95110.1103
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 1.3626.844.928.31.51

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.33    
<2 mm air-dry   0.30 0.20
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 92KS079006
Layer Natural Key: 92P03165
Horizon: Ap2   12.0-26.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.08530.4115-1.50250.0773
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 0.9926.140.633.31.55

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.33    
<2 mm air-dry   0.34 0.25
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 92KS079006
Layer Natural Key: 92P03166
Horizon: Btn   26.0-50.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.07520.4665-2.47320.1481
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 0.5826.535.937.61.43

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.42    
<2 mm air-dry   0.36 0.24
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 92KS079006
Layer Natural Key: 92P03167
Horizon: Btzg   50.0-75.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.07150.4472-2.48240.1645
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 0.2927.638.733.71.46

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.39    
<2 mm air-dry   0.31 0.21
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 92KS079006
Layer Natural Key: 92P03168
Horizon: Btksszg1   75.0-108.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.07450.4614-2.34100.0938
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% vol% wt% wt% wt% wtg/cc
70.276.353.440.31.57

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.45    
<2 mm air-dry   0.43 0.30
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 92KS079006
Layer Natural Key: 92P03170
Horizon: Btg1   123.0-149.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.08760.5003-2.11950.0972
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 0.182.455.242.41.38

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.44    
<2 mm air-dry   0.43 0.29
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 92KS079006
Layer Natural Key: 92P03171
Horizon: Btg2   149.0-171.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.08290.4916-2.39320.1037
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 0.132.456.341.31.48

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.47    
<2 mm air-dry   0.46 0.31
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 92KS079006
Layer Natural Key: 92P03172
Horizon: BCg   171.0-231.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.06970.4292-2.17680.1122
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 0.1115.054.330.71.55

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.38    
<2 mm air-dry   0.34 0.22
 

Soil Water Retention Curve




*Rosetta Reference NSSC SSL Report Creation