ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 92OR003002
Layer Natural Key: 92P04667
Horizon: Ap1   0.0-17.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.06750.4907-2.49100.2338
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 2.844.671.523.91.14

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.37    
<2 mm air-dry   0.23 0.14
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 92OR003002
Layer Natural Key: 92P04668
Horizon: Ap2   17.0-31.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.07100.4475-2.36050.1784
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 2.034.169.826.11.42

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.35    
<2 mm air-dry   0.28 0.17
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 92OR003002
Layer Natural Key: 92P04669
Horizon: AB   31.0-49.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.07300.4486-2.40300.1812
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 1.423.770.226.11.44

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.36    
<2 mm air-dry   0.27 0.17
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 92OR003002
Layer Natural Key: 92P04670
Horizon: BA   49.0-69.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.07110.4340-2.61930.2244
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 0.604.174.421.51.53

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.37    
<2 mm air-dry   0.27 0.16
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 92OR003002
Layer Natural Key: 92P04671
Horizon: Bt/E   69.0-91.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.06870.4233-2.07580.1149
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 0.303.870.725.51.56

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.35    
<2 mm air-dry   0.33 0.20
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 92OR003002
Layer Natural Key: 92P04672
Horizon: 2Bt1   91.0-108.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.08320.4673-1.99750.0978
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 0.192.567.929.61.45

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.39    
<2 mm air-dry   0.37 0.25
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 92OR003002
Layer Natural Key: 92P04673
Horizon: 2Bt2   108.0-124.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.08870.4898-2.37930.1606
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 0.143.069.127.91.36

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.41    
<2 mm air-dry   0.34 0.22
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 92OR003002
Layer Natural Key: 92P04674
Horizon: 2BCt   124.0-180.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.09530.4939-2.70600.2417
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 0.063.873.023.21.36

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.43    
<2 mm air-dry   0.31 0.20
 

Soil Water Retention Curve




*Rosetta Reference NSSC SSL Report Creation