ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 92UT019104A
Layer Natural Key: 92P04731
Horizon: A   0.0-9.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.07560.4942-2.12000.1545
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 2.005.957.236.91.20

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.35    
<2 mm air-dry     0.17
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 92UT019104A
Layer Natural Key: 92P04732
Horizon: C   9.0-17.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.05000.4128-2.58200.2464
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 0.8324.557.218.31.37

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.33    
<2 mm air-dry     0.10
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 92UT019104A
Layer Natural Key: 92P04733
Horizon: Ab   17.0-21.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.06500.5446-1.53720.1222
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 3.3413.948.038.10.94

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.28    
<2 mm air-dry     0.15
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 92UT019104A
Layer Natural Key: 92P04734
Horizon: C1   21.0-52.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.07920.4608-1.79070.1138
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 0.7312.046.641.41.35

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.32    
<2 mm air-dry     0.19
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 92UT019104A
Layer Natural Key: 92P04735
Horizon: C2   52.0-90.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.02730.3948-2.23380.1878
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 0.5341.747.311.01.29

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.26    
<2 mm air-dry     0.07
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 92UT019104A
Layer Natural Key: 92P04736
Horizon: Ab   90.0-99.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.05550.4445-2.48940.2299
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 0.6312.666.520.91.27

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.34    
<2 mm air-dry     0.12
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 92UT019104A
Layer Natural Key: 92P04737
Horizon: CByb   99.0-131.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.07930.4432-1.63290.1119
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 0.5413.350.935.81.37

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.29    
<2 mm air-dry     0.18
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 92UT019104A
Layer Natural Key: 92P04738
Horizon: C3   131.0-150.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.01870.4157-1.43340.1269
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% wt% wt% wt% wtg/cc
 0.1781.313.45.31.35

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.16    
<2 mm air-dry     0.04
 

Soil Water Retention Curve




*Rosetta Reference NSSC SSL Report Creation