*** Supplementary Characterization Data ***
Pedon ID: S1997OR023012( Grant, Oregon )Print Date: Nov 24 2024 4:06AM

Sampled as on Sep 29, 1997:DRYBED ; Fine-loamy, mixed Calciargidic Argixerolls
Revised to :
United States Department of Agriculture
SSL-ProjectRP98OR053   GRANT COUNTYNatural Resources Conservation Service
-Site IDS1997OR023012   Lat: 44° 48' 14.00" north  Long: 119° 32' 44.00" westNational Soil Survey Center
-Pedon No. 98P0222Soil Survey Laboratory
-General Methods 1B1A, 2A1, 2BLincoln, Nebraska 68508-3866

Tier 1-1--2--3--4--5--6--7--8--9--10--11--12--13--14--15--16--17--18--19--20--21--22--23--24--25-
 
(- - - - - - - - - - - - - - - - - - - - - - Engineering PSDA - - - - - - - - - - - - - - - - - - - - -)(- - - - - Cumulative Curve Fractions - - - - -) (<75mm)( Atter- )( Gradation )
Percentage Passing SieveUSDA Less Than Diameters (mm) at bergUni-Cur-
Depth323/213/43/84104020020521..5.25.10.05605010LLPIfmtyvtur
Layer(cm)HorzPrep(-------------------Inches-------------------)(---------Number---------)(------Microns----)(---------Millimeter----------)(-----Percentile---)(----%----)CUCC
 
98P013450-20ApS10010010010010010010099936741251498948873600.050.0310.00151.11.2
98P0134620-33Bt1S1001001009999999998916441271796938670570.060.0330.00176.21.1
98P0134733-48Bt2S10010010010010010010099936941251598958875610.050.0300.00150.91.3
98P0134848-89BkS10010010010010099989584562614591867863470.090.0580.00326.51.9
98P0134989-107BCkS1001001001001001001009680603319990827465530.080.0440.00234.01.3
98P01350107-152CS1001001001001009895825225127470564129200.620.3830.01154.91.7

Tier 2-26--27--28--29--30--31--32--33--34--35--36--37--38--39--40--41--42--43--44--45--46--47--48--49--50-
 
(- - - - - - - - - - - - - - - - - - - - - - Weight Fractions - - - - - - - - - - - - - - - - - - - - -)(- - - - - - - - - - - Weight Per Unit Volume (g cm-3 )- - - - - - - -)(- - Void - -)
Whole Soil (mm)<75 mm FractionWhole Soil<2 mm FractionRatios
>225025075752057575205Soil SurEngineeringSoil SurveyEngineeringAt 33 kPa
Depth-UP-75-2-20-5-2<2-2-20-5-2<233OvenMoistSatur331500OvenMoistSaturWhole<2
Layer(cm)HorzPrep(------------------- % of Whole Soil ------------------)(--------- % of <75 mm ---------)kPa-dry-ated kPa kPa -dry -ated Soilmm
3B13B13B1
 
98P013450-20ApS1----1----1991--tr1991.461
98P0134620-33Bt1S2----21--19821tr1981.461
98P0134733-48Bt2S1----1----1991--tr1991.461
98P0134848-89BkS5----5--23955--23951.481
98P0134989-107BCkS4----4--tr4964--tr4961.481
98P01350107-152CS18----18--5138218--513821.581

1The whole-soil bulk density was not measured. It was calculated using 1.45 g/cc as the 1/3-bar bulk density of the less-than-2-mm fraction for mineral soils.


*** Supplementary Characterization Data ***
Pedon ID: S1997OR023012( Grant, Oregon )Print Date: Nov 24 2024 4:06AM
Sampled As:DRYBEDFine-loamy, mixed Calciargidic Argixerolls
USDA-NRCS-NSSC-Soil Survey Laboratory;Pedon No.  98P0222

Tier 3-51--52--53--54--55--56--57--58--59--60--61--62--63--64--65--66--67--68--69--70--71--72--73--74--75-
 
(- - - - - - - - - - - - - - - - - Volume Fractions - - - - - - - - - - - - - - - -)C(- - - - - - - Ratios To Clay - - - - - -)(- - Linear Extensiblity - -)(- - WRD - -)
Whole Soil (mm) At 33 kPa/N<2 mm FractionWhole Soil<2 mmWhole<2
>225025075752052-.05-LTPoresRatFineCEC1500LEP33 kPato %Soilmm
Depth-UP-75-2-20-5-2<2.05.002.002DF-ioClaySumNH4-kPa331500Oven1500Oven
Layer(cm)HorzPrep(----------------------------- % of Whole Soil ---------------------------)CatsOACH2OkPakPa-drykPa-dry(---in3/in3---)
8D1
 
98P013450-20ApS1----1----19922258450.291.710.69
98P0134620-33Bt1S1----11--19922229450.231.710.76
98P0134733-48Bt2S1----1----19921258450.052.450.89
98P0134848-89BkS3----3--129727233441.75
98P0134989-107BCkS2----2--tr29824245441.10
98P01350107-152CS11----11--38893693401.06

Tier 4-76--77--78--79--80--81--82--83--84--85--86--87--88--89--90--91--92--93--94--95--96--97--98-
 
(- - - - - - - - - - - - - - - - - - - Weight Fractions - Clay Free - - - - - - - - - - - - - - - - - -)TextPSDA (mm)pHElect.Part-
(--------------- Whole Soil ---------------)(------------------- <2 mm Fraction -------------------)-ureSandSiltClayCaRes-Con--icle
>275202-.05-<(------------- Sands -------------)(--- Silts ---)Clby2-.05-<Cl2ist.ductDen-
Depth-20-2.05.002.002VCCMFVFCFayPSDA.05.002.002.01MohmsdS m-1sity
Layer(cm)HorzPrep(- % of >2 mm Sand and Silt -)(------------------% of Sand and Silt -------------)<2 mm(---- % of 2 mm ----)(-------- <2 mm --------)g cm-3
3A1a1a3A1a1a3A1a1a3A1a1a4C1a2a
 
98P013450-20ApS1114653172471716233117l39.545.914.66.2
98P0134620-33Bt1S2214948212582016212921l41.540.917.66.5
98P0134733-48Bt2S1114554171481617243118l38.546.515.07.7
98P0134848-89BkS55551446568171823236fsl51.043.45.68.2
98P0134989-107BCkS4444848107991114222810l45.345.59.28.4
98P01350107-152CS19191965175161818161111106cosl75.219.45.48.4
NSSC SSL Report Creation