*** Andic Soil Properties Data ***
Pedon ID: S1999MN005007( Becker, Minnesota )Print Date: Jun 1 2024 1:43AM

Sampled as on Oct 26, 1999:BEARDEN ; Fine-silty, mixed, superactive, frigid Aeric Calciaquolls
Revised to SSL:(unnamed) ; Fine-silty, mixed, superactive, frigid Aeric Calciaquoll
United States Department of Agriculture
SSL-ProjectCP99MN155   MINNESOTA HAMDEN SLOUGHNatural Resources Conservation Service
-Site IDS1999MN005007   Lat: 46° 5921.90" north  Long: 95° 5841.69" westNational Soil Survey Center
-Pedon No. 99P0519Soil Survey Laboratory
-General Methods 1B1A, 2A1, 2BLincoln, Nebraska 68508-3866

Andic Soil Properties Tier 1-1--2--3--4--5--6--7--8--9--10--11--12--13--14--15--16--17--18--19--20--21-
 
TotalFineCaCO3CoSi toEst.1-75Vol >2mmBulkCOLEAl+½FeAl+½Fe
ClayClayClayVCoSClayFraction% of(- - - - 1500 kPa - - - -)DensityWhole(- - - - - - - - - - Glass Content - - - - - - - - - -)*15.625*60.0
Depth<.002<.0002<.002.02 - 2ContentWhole Soilair-dryfield moist/Clay33 kPaSoilcsivfsfsmscsvcsWt Avg+Glass+Glass
Layer(cm)HorzPrep(- - - - - - - - - - - % of <2 mm - - - - - - - - -)% of <75 mm(- - - - - - - - % - - - - - - -)g cm-3cm cm-1(- - - - - - - - - - - - - - - - - - - - - % - - - - - - - - - - - - - - - - - - - - -)
3A1a1a3A1a1a3A1a1a3C2a1a8D14A1d
 
99P037120-7Ap1S32.016.312tr30.50.950.930.106
99P037137-25Ap2S34.716.59--30.80.890.930.109
99P0371425-44AS31.715.513tr21.60.681.120.051
99P0371544-51Bk1S36.013.114.511tr14.80.411.480.031
99P0371651-73Bk2S21.38.94.35--9.40.441.610.010
99P0371773-1122Bk3S16.16.42.119--7.40.461.540.021
99P03718112-1272C1S14.85.71.524--7.30.491.580.017
99P03719127-1412C2S21.18.113110.80.511.470.045
99P03720141-2063C3S30.912.1tr--18.00.58

Andic Soil Properties Tier 2-1--2--3--4--5--6--7--8--9--10--11--12--13--14--15--16--17--18--19-
 
CO3Al+8*SiOpticalKClNH4OACSum(- Base Sat -)
pHpHOrgTotasNZ½Fe8*Si2*Fe+2*FeDensityExtrSumBases+NH4OACSum ofMelanic(- Atterberg -)
DepthH2ONaFCCCaCO3P RetOxalOxalOxalOxalOxalAlBasesExtr AlpH 7.0CationsIndexLLPI
Layer(cm)HorzPrep(- - - - - - - - - - - - - - - - - - - - - - - % wt - - - - - - - - - - - - - - - - - -)cmol(+) kg-1(- meq 100g-1 -)(- - - - % - - - - -)( % <0.4mm )
4C1a2a6A2e4E1a1a1a18J1c
 
99P037120-7Ap1S8.011.37150.170.67
99P037137-25Ap2S7.811.86130.170.75
99P0371425-44AS7.85.7730.170.15
99P0371544-51Bk1S7.95.53360.150.08
99P0371651-73Bk2S7.84.31340.090.06
99P0371773-1122Bk3S8.03.14260.060.02
99P03718112-1272C1S7.92.68240.090.05
99P03719127-1412C2S7.83.21270.140.04
99P03720141-2063C3S7.94.36330.200.06


NSSC SSL Report Creation