*** Supplementary Characterization Data ***
Pedon ID: 1929IL133002( Monroe, Illinois )Print Date: Nov 24 2024 1:06AM

Sampled as on Sep 29, 1929:Stoy
Revised to correlated:Muren ; Fine-silty, mixed, superactive, mesic Aquic Hapludalfs
State of Illinois
SSL-ProjectIL200802   University of Illinois, Soil Characterization Data Book #01University of Illinois
-Site ID1929IL133002   Lat: 38° 16' 16.79" north  Long: 90° 14' 11.75" west  MLRA: 115BSoil Characterization Laboratory
-Pedon No. 29IL133002Department of Natural Resources and Environmental Science
-General Methods 1B1A, 2A1, 2BUrbana, Illinois

Tier 3-51--52--53--54--55--56--57--58--59--60--61--62--63--64--65--66--67--68--69--70--71--72--73--74--75-
 
(- - - - - - - - - - - - - - - - - Volume Fractions - - - - - - - - - - - - - - - -)C(- - - - - - - Ratios To Clay - - - - - -)(- - Linear Extensiblity - -)(- - WRD - -)
Whole Soil (mm) At 33 kPa/N<2 mm FractionWhole Soil<2 mmWhole<2
>225025075752052-.05-LTPoresRatFineCEC1500LEP33 kPato %Soilmm
Depth-UP-75-2-20-5-2<2.05.002.002DF-ioClaySumNH4-kPa331500Oven1500Oven
Layer(cm)HorzPrep(----------------------------- % of Whole Soil ---------------------------)CatsOACH2OkPakPa-drykPa-dry(---in3/in3---)
 
IL136700-18ApS
IL1367118-30A2S
IL1367230-41A2S
IL1367341-53B1S
IL1367453-74B21S
IL1367574-99B22S
IL1367699-132B23S
IL13677132-155B31S
IL13678155-175B32S
IL13679175-201B32S
IL13680201-224CS


*** Supplementary Characterization Data ***
Pedon ID: 1929IL133002( Monroe, Illinois )Print Date: Nov 24 2024 1:06AM
Sampled As:Stoy
University of Illinois Soil Survey Laboratory;Pedon No.  29IL133002

Tier 4-76--77--78--79--80--81--82--83--84--85--86--87--88--89--90--91--92--93--94--95--96--97--98-
 
(- - - - - - - - - - - - - - - - - - - Weight Fractions - Clay Free - - - - - - - - - - - - - - - - - -)TextPSDA (mm)pHElect.Part-
(--------------- Whole Soil ---------------)(------------------- <2 mm Fraction -------------------)-ureSandSiltClayCaRes-Con--icle
>275202-.05-<(------------- Sands -------------)(--- Silts ---)Clby2-.05-<Cl2ist.ductDen-
Depth-20-2.05.002.002VCCMFVFCFayPSDA.05.002.002.01MohmsdS m-1sity
Layer(cm)HorzPrep(- % of >2 mm Sand and Silt -)(------------------% of Sand and Silt -------------)<2 mm(---- % of 2 mm ----)(-------- <2 mm --------)g cm-3
3A1a1a3A1a1a3A1a1a3A1a1a
 
IL136700-18ApSsi3.085.010.0
IL1367118-30A2Ssil2.084.012.0
IL1367230-41A2Ssil2.083.013.0
IL1367341-53B1Ssil2.081.016.0
IL1367453-74B21Ssil2.075.022.0
IL1367574-99B22Ssicl1.067.030.0
IL1367699-132B23Ssicl1.067.030.0
IL13677132-155B31Ssicl1.070.027.0
IL13678155-175B32Ssil1.073.025.0
IL13679175-201B32Ssil1.076.022.0
IL13680201-224CSsil1.080.018.0
NSSC SSL Report Creation