*** Supplementary Characterization Data ***
Pedon ID: 1930IL095004( Knox, Illinois )Print Date: Sep 24 2024 5:29AM

Sampled as on Sep 29, 1930:Tama
Revised to correlated on Feb 20, 2010:Buckhart ; Fine-silty, mixed, superactive, mesic Oxyaquic Argiudolls
State of Illinois
SSL-ProjectIL200802   University of Illinois, Soil Characterization Data Book #01University of Illinois
-Site ID1930IL095004   Lat: 41° 2' 5.64" north  Long: 90° 8' 20.31" west  MLRA: 115CSoil Characterization Laboratory
-Pedon No. 30IL095004Department of Natural Resources and Environmental Science
-General Methods 1B1A, 2A1, 2BUrbana, Illinois

Tier 3-51--52--53--54--55--56--57--58--59--60--61--62--63--64--65--66--67--68--69--70--71--72--73--74--75-
 
(- - - - - - - - - - - - - - - - - Volume Fractions - - - - - - - - - - - - - - - -)C(- - - - - - - Ratios To Clay - - - - - -)(- - Linear Extensiblity - -)(- - WRD - -)
Whole Soil (mm) At 33 kPa/N<2 mm FractionWhole Soil<2 mmWhole<2
>225025075752052-.05-LTPoresRatFineCEC1500LEP33 kPato %Soilmm
Depth-UP-75-2-20-5-2<2.05.002.002DF-ioClaySumNH4-kPa331500Oven1500Oven
Layer(cm)HorzPrep(----------------------------- % of Whole Soil ---------------------------)CatsOACH2OkPakPa-drykPa-dry(---in3/in3---)
 
IL139150-15A11S
IL1391615-25A12S
IL1391725-33A3S
IL1391833-46B1S
IL1391946-74B21S
IL1392074-89B22S
IL1392189-104B31S
IL13922104-135B32S
IL13923135-155C11S
IL13924155-180C11S
IL13925180-218C12S


*** Supplementary Characterization Data ***
Pedon ID: 1930IL095004( Knox, Illinois )Print Date: Sep 24 2024 5:29AM
Sampled As:Tama
University of Illinois Soil Survey Laboratory;Pedon No.  30IL095004

Tier 4-76--77--78--79--80--81--82--83--84--85--86--87--88--89--90--91--92--93--94--95--96--97--98-
 
(- - - - - - - - - - - - - - - - - - - Weight Fractions - Clay Free - - - - - - - - - - - - - - - - - -)TextPSDA (mm)pHElect.Part-
(--------------- Whole Soil ---------------)(------------------- <2 mm Fraction -------------------)-ureSandSiltClayCaRes-Con--icle
>275202-.05-<(------------- Sands -------------)(--- Silts ---)Clby2-.05-<Cl2ist.ductDen-
Depth-20-2.05.002.002VCCMFVFCFayPSDA.05.002.002.01MohmsdS m-1sity
Layer(cm)HorzPrep(- % of >2 mm Sand and Silt -)(------------------% of Sand and Silt -------------)<2 mm(---- % of 2 mm ----)(-------- <2 mm --------)g cm-3
3A1a1a3A1a1a3A1a1a3A1a1a
 
IL139150-15A11Ssil2.071.026.0
IL1391615-25A12Ssicl1.069.029.0
IL1391725-33A3Ssicl--67.031.0
IL1391833-46B1Ssicl--66.033.0
IL1391946-74B21Ssicl--65.033.0
IL1392074-89B22Ssicl--67.031.0
IL1392189-104B31Ssicl--71.028.0
IL13922104-135B32Ssil--73.026.0
IL13923135-155C11Ssil--75.023.0
IL13924155-180C11Ssil--75.023.0
IL13925180-218C12Ssil--81.018.0
NSSC SSL Report Creation