*** Supplementary Characterization Data ***
Pedon ID: S2009UT033001( Rich, Utah )Print Date: Nov 21 2024 1:24PM

Sampled as on Jun 20, 2009:Solak ; Loamy-skeletal, calcareous, superactive, frigid Lithic Xeric Torriorthents
Revised to :
United States Department of Agriculture
SSL-ProjectC2009USNL133   Climate Monitoring Stations SNOTEL/SCAN Natural Resources Conservation Service
-Site IDS2009UT033001   Lat: 41° 20' 36.80" north  Long: 111° 11' 16.29" westNational Soil Survey Center
-Pedon No. 09N1054Kellogg Soil Survey Laboratory
-General Methods 1B1A, 2A1, 2BLincoln, Nebraska 68508-3866

Tier 1-1--2--3--4--5--6--7--8--9--10--11--12--13--14--15--16--17--18--19--20--21--22--23--24--25-
 
(- - - - - - - - - - - - - - - - - - - - - - Engineering PSDA - - - - - - - - - - - - - - - - - - - - -)(- - - - - Cumulative Curve Fractions - - - - -) (<75mm)( Atter- )( Gradation )
Percentage Passing SieveUSDA Less Than Diameters (mm) at bergUni-Cur-
Depth323/213/43/84104020020521..5.25.10.05605010LLPIfmtyvtur
Layer(cm)HorzPrep(-------------------Inches-------------------)(---------Number---------)(------Microns----)(---------Millimeter----------)(-----Percentile---)(----%----)CUCC
 
09N041580-20AS100100100100100989691856229191389878170480.070.0540.00158.84.7
09N0415920-30ABS10099999897887876746036272175747265510.080.0460.001>1001.4
09N0416030-51BkqS1001001009999979490867147342689878477640.040.024tr83.70.5
09N0416151-100BkqmS10098969492786351433524161148444138323.801.6170.002>1000.2

Tier 2-26--27--28--29--30--31--32--33--34--35--36--37--38--39--40--41--42--43--44--45--46--47--48--49--50-
 
(- - - - - - - - - - - - - - - - - - - - - - Weight Fractions - - - - - - - - - - - - - - - - - - - - -)(- - - - - - - - - - - Weight Per Unit Volume (g cm-3 )- - - - - - - -)(- - Void - -)
Whole Soil (mm)<75 mm FractionWhole Soil<2 mm FractionRatios
>225025075752057575205Soil SurEngineeringSoil SurveyEngineeringAt 33 kPa
Depth-UP-75-2-20-5-2<2-2-20-5-2<233OvenMoistSatur331500OvenMoistSaturWhole<2
Layer(cm)HorzPrep(------------------- % of Whole Soil ------------------)(--------- % of <75 mm ---------)kPa-dry-ated kPa kPa -dry -ated Soilmm
DbWR1DbWR1
 
09N041580-20AS99--45919--45911.181.231.491.731.121.161.171.441.701.251.37
09N0415920-30ABS2424319276243192761.351.451.661.841.171.231.271.531.730.961.26
09N0416030-51BkqS10101549010154901.361.431.711.851.301.341.371.681.810.951.04
09N0416151-100BkqmS494982912514982912511.8512.153

1The whole-soil bulk density was not measured. It was calculated using 1.45 g/cc as the 1/3-bar bulk density of the less-than-2-mm fraction for mineral soils.
3The saturated whole-soil bulk density was not measured. It was calculated using 1.45 g/cc as the 1/3-bar bulk density of the less-than-2-mm fraction for mineral soils.
Tier 3-51--52--53--54--55--56--57--58--59--60--61--62--63--64--65--66--67--68--69--70--71--72--73--74--75-
 
(- - - - - - - - - - - - - - - - - Volume Fractions - - - - - - - - - - - - - - - -)C(- - - - - - - Ratios To Clay - - - - - -)(- - Linear Extensiblity - -)(- - WRD - -)
Whole Soil (mm) At 33 kPa/N<2 mm FractionWhole Soil<2 mmWhole<2
>225025075752052-.05-LTPoresRatFineCEC1500LEP33 kPato %Soilmm
Depth-UP-75-2-20-5-2<2.05.002.002DF-ioClaySumNH4-kPa331500Oven1500Oven
Layer(cm)HorzPrep(----------------------------- % of Whole Soil ---------------------------)CatsOACH2OkPakPa-drykPa-dry(---in3/in3---)
 
09N041580-20AS4----4--2296201662431100.580.1091.11.41.21.50.220.23
09N0415920-30ABS12----122101881316111831110.480.1021.52.41.72.80.180.21
09N0416030-51BkqS5----5132951420141435110.380.0621.01.71.01.80.220.23
09N0416151-100BkqmS34----346208661315890.42


*** Supplementary Characterization Data ***
Pedon ID: S2009UT033001( Rich, Utah )Print Date: Nov 21 2024 1:24PM
Sampled As:SolakLoamy-skeletal, calcareous, superactive, frigid Lithic Xeric Torriorthents
USDA-NRCS-NSSC-Soil Survey Laboratory;Pedon No.  09N1054

Tier 4-76--77--78--79--80--81--82--83--84--85--86--87--88--89--90--91--92--93--94--95--96--97--98-
 
(- - - - - - - - - - - - - - - - - - - Weight Fractions - Clay Free - - - - - - - - - - - - - - - - - -)TextPSDA (mm)pHElect.Part-
(--------------- Whole Soil ---------------)(------------------- <2 mm Fraction -------------------)-ureSandSiltClayCaRes-Con--icle
>275202-.05-<(------------- Sands -------------)(--- Silts ---)Clby2-.05-<Cl2ist.ductDen-
Depth-20-2.05.002.002VCCMFVFCFayPSDA.05.002.002.01MohmsdS m-1sity
Layer(cm)HorzPrep(- % of >2 mm Sand and Silt -)(------------------% of Sand and Silt -------------)<2 mm(---- % of 2 mm ----)(-------- <2 mm --------)g cm-3
3A1a1a4C1a2a4F2
 
09N041580-20AS1010105040143371528232116l47.738.513.87.51.57
09N0415920-30ABS3030273139261251225282738cl32.440.127.57.6
09N0416030-51BkqS1414123551362351120283241cl28.742.129.27.7
09N0416151-100BkqmS5555462124128106913203328l36.741.721.67.90.86
NSSC SSL Report Creation