*** Supplementary Characterization Data ***
Pedon ID: 2007MO183006( St. Charles, Missouri )Print Date: Nov 21 2024 2:04PM

Sampled as on Mar 4, 2007:SND ; Fine, smectitic, superactive, mesic Fluvaquentic Vertic Endoaquolls
Revised to correlated:SANSDESSEIN ; Fine, smectitic, superactive, mesic Fluvaquentic Vertic Endoaquolls
State of Missouri
SSL-ProjectMO201001   University of Missouri Project 1University of Missouri
-Site ID2007MO183006   Lat: 38° 34' 23.90" north  Long: 90° 47' 18.90" west  MLRA: 115BCollege of Engineering
-Pedon No. M0718306Soil Characterization Laboratory
-General Methods 1B1A, 2A1, 2BColumbia, Missouri 65211

Tier 3-51--52--53--54--55--56--57--58--59--60--61--62--63--64--65--66--67--68--69--70--71--72--73--74--75-
 
(- - - - - - - - - - - - - - - - - Volume Fractions - - - - - - - - - - - - - - - -)C(- - - - - - - Ratios To Clay - - - - - -)(- - Linear Extensiblity - -)(- - WRD - -)
Whole Soil (mm) At 33 kPa/N<2 mm FractionWhole Soil<2 mmWhole<2
>225025075752052-.05-LTPoresRatFineCEC1500LEP33 kPato %Soilmm
Depth-UP-75-2-20-5-2<2.05.002.002DF-ioClaySumNH4-kPa331500Oven1500Oven
Layer(cm)HorzPrep(----------------------------- % of Whole Soil ---------------------------)CatsOACH2OkPakPa-drykPa-dry(---in3/in3---)
 
MU0072030-10ApS
MU00720410-36AS
MU00720536-43Bg1S
MU00720643-71Bg2S
MU00720771-97Bg3S
MU00720897-109Bg4S
MU007209109-140Cg1S
MU007210140-203Cg2S

Tier 4-76--77--78--79--80--81--82--83--84--85--86--87--88--89--90--91--92--93--94--95--96--97--98-
 
(- - - - - - - - - - - - - - - - - - - Weight Fractions - Clay Free - - - - - - - - - - - - - - - - - -)TextPSDA (mm)pHElect.Part-
(--------------- Whole Soil ---------------)(------------------- <2 mm Fraction -------------------)-ureSandSiltClayCaRes-Con--icle
>275202-.05-<(------------- Sands -------------)(--- Silts ---)Clby2-.05-<Cl2ist.ductDen-
Depth-20-2.05.002.002VCCMFVFCFayPSDA.05.002.002.01MohmsdS m-1sity
Layer(cm)HorzPrep(- % of >2 mm Sand and Silt -)(------------------% of Sand and Silt -------------)<2 mm(---- % of 2 mm ----)(-------- <2 mm --------)g cm-3
3A1a1a8C1e
 
MU0072030-10ApS1----12336371SIC2.356.241.57.3
MU00720410-36AS------13257193SIC1.750.248.17.3
MU00720536-43Bg1S------819423027SIL21.856.921.37.5
MU00720643-71Bg2S------131977103SIC2.147.150.87.6
MU00720771-97Bg3S----------2080121SIC0.345.054.77.6
MU00720897-109Bg4S--------11484124SIC0.744.055.37.6
MU007209109-140Cg1S--------17691410SIL15.675.09.47.7
MU007210140-203Cg2S----11423511210SIL34.356.69.17.7
NSSC SSL Report Creation