ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 67PA061012
Layer Natural Key: PSU02996
Horizon: Ap   0.0-20.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.05900.4675-2.50680.2278
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% vol% wt% wt% wt% wtg/cc
142.2310.667.322.11.10

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.35    
Core  0.31    
<2 mm air-dry      0.08
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 67PA061012
Layer Natural Key: PSU02997
Horizon: E   20.0-36.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.08060.4465-2.75730.2839
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% vol% wt% wt% wt% wtg/cc
240.5114.466.019.61.32

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.38    
Core  0.29    
<2 mm air-dry      0.10
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 67PA061012
Layer Natural Key: PSU02998
Horizon: BA   36.0-53.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.09050.4184-1.73290.0790
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% vol% wt% wt% wt% wtg/cc
110.2110.355.434.31.53

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.33    
Core  0.31    
<2 mm air-dry      0.21
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 67PA061012
Layer Natural Key: PSU02999
Horizon: Bt1   53.0-89.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.09600.4254-1.67330.0667
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% vol% wt% wt% wt% wtg/cc
150.1110.445.544.11.55

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.35    
Core  0.31    
<2 mm air-dry      0.24
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 67PA061012
Layer Natural Key: PSU03000
Horizon: Bt2   89.0-117.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.10200.4137-1.53730.0610
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% vol% wt% wt% wt% wtg/cc
180.076.748.045.31.59

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.34    
Core  0.31    
<2 mm air-dry      0.24
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 67PA061012
Layer Natural Key: PSU03001
Horizon: Bt3   117.0-140.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.13050.4371-1.36120.0585
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% vol% wt% wt% wt% wtg/cc
10.099.345.645.11.51

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.36    
Core  0.35    
<2 mm air-dry      0.28
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 67PA061012
Layer Natural Key: PSU03002
Horizon: Bt4   140.0-165.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.11120.4277-1.45570.0502
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% vol% wt% wt% wt% wtg/cc
20.097.441.251.41.58

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.37    
Core  0.37    
<2 mm air-dry      0.29
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 67PA061012
Layer Natural Key: PSU03003
Horizon: Bt5   165.0-188.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.11480.4431-1.46080.0503
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% vol% wt% wt% wt% wtg/cc
10.097.037.255.81.54

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.38    
Core  0.38    
<2 mm air-dry      0.30
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 67PA061012
Layer Natural Key: PSU03004
Horizon: Bt6   188.0-241.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.10100.5041-2.06320.0879
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% vol% wt% wt% wt% wtg/cc
30.096.733.959.41.36

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.42    
Core  0.42    
<2 mm air-dry      0.27
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 67PA061012
Layer Natural Key: PSU03005
Horizon: C1   241.0-257.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.08370.4486-1.98510.1153
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% vol% wt% wt% wt% wtg/cc
190.0819.644.835.61.37

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.33    
Core  0.32    
<2 mm air-dry      0.17
 

Soil Water Retention Curve




*Rosetta Reference


ESTIMATED SOIL WATER RETENTION CURVE
<2 mm Fraction
Pedon ID: 67PA061012
Layer Natural Key: PSU03006
Horizon: C2   257.0-300.0 cm
van Genuchten Retention Parameters from Rosetta*
qrqslog10(a)log10(n)
0.09420.4995-2.39830.1650
Measured Soil Properties
Rock FragmentOrganic CarbonSandSiltClayDb33
% vol% wt% wt% wt% wtg/cc
720.1531.530.038.51.23

 
Sample Typeq6 kPaq10 kPaq33 kPaq100 kPaq200 kPaq500 kPaq1500 kPa
 cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3cm3/cm3
Clod  0.40    
Core  0.29    
<2 mm air-dry      0.19
 

Soil Water Retention Curve




*Rosetta Reference NSSC SSL Report Creation