*** Andic Soil Properties Data ***
Pedon ID: 1980PA069012( Lackawanna, Pennsylvania )Print Date: May 14 2024 5:09PM

Sampled as on Apr 23, 1980:Volusia
Revised to correlated:Volusia ; Coarse-loamy, mixed Aeric Fragiaquepts
State of Pennsylvania
SSL-ProjectPSU201101   The Pennsylvania State University DataThe Pennsylvania State University
-Site ID466   Lat: 41° 310.00" north  Long: 75° 3854.00" west  MLRA: 140Department of Crop and Soil Sciences
-Pedon No. 80PA069012452 ASI Building
-General Methods 1B1A, 2A1, 2BUniversity Park, PA 16802-3504

Andic Soil Properties Tier 1-1--2--3--4--5--6--7--8--9--10--11--12--13--14--15--16--17--18--19--20--21-
 
TotalFineCaCO3CoSi toEst.1-75Vol >2mmBulkCOLEAl+½FeAl+½Fe
ClayClayClayVCoSClayFraction% of(- - - - 1500 kPa - - - -)DensityWhole(- - - - - - - - - - Glass Content - - - - - - - - - -)*15.625*60.0
Depth<.002<.0002<.002.02 - 2ContentWhole Soilair-dryfield moist/Clay33 kPaSoilcsivfsfsmscsvcsWt Avg+Glass+Glass
Layer(cm)HorzPrep(- - - - - - - - - - - % of <2 mm - - - - - - - - -)% of <75 mm(- - - - - - - - % - - - - - - -)g cm-3cm cm-1(- - - - - - - - - - - - - - - - - - - - - % - - - - - - - - - - - - - - - - - - - - -)
3A1a1a3C2a1aDbWR1
 
PSU035030-23ApS17.410.40.60
PSU0350423-36ES12.3175.30.431.65
PSU0350536-58Bx1S18.9177.40.391.78
PSU0350658-81Bx2S19.9137.70.391.80
PSU0350781-104Bx3S19.0197.80.411.85
PSU03508104-127Bx4S21.1277.80.371.85
PSU03509127-152Bx5S17.7276.90.391.81
PSU03510152-190Bx6S18.1176.90.381.84
PSU03511190-2102Bx7S17.5187.20.411.81

Andic Soil Properties Tier 2-1--2--3--4--5--6--7--8--9--10--11--12--13--14--15--16--17--18--19-
 
CO3Al+8*SiOpticalKClNH4OACSum(- Base Sat -)
pHpHOrgTotasNZ½Fe8*Si2*Fe+2*FeDensityExtrSumBases+NH4OACSum ofMelanic(- Atterberg -)
DepthH2ONaFCCCaCO3P RetOxalOxalOxalOxalOxalAlBasesExtr AlpH 7.0CationsIndexLLPI
Layer(cm)HorzPrep(- - - - - - - - - - - - - - - - - - - - - - - % wt - - - - - - - - - - - - - - - - - -)cmol(+) kg-1(- meq 100g-1 -)(- - - - % - - - - -)( % <0.4mm )
8C1aNK
 
PSU035030-23ApS5.42.290.1
PSU0350423-36ES5.30.180.5
PSU0350536-58Bx1S4.40.062.1
PSU0350658-81Bx2S4.50.052.2
PSU0350781-104Bx3S4.90.041.0
PSU03508104-127Bx4S5.10.030.6
PSU03509127-152Bx5S5.30.040.3
PSU03510152-190Bx6S5.70.040.2
PSU03511190-2102Bx7S6.20.1


NSSC SSL Report Creation