*** Andic Soil Properties Data ***
Pedon ID: 1977PA071021( Lancaster, Pennsylvania )Print Date: Nov 23 2024 7:09AM

Sampled as on Jun 12, 1977:Hollinger
Revised to correlated:Hollinger ; Fine-loamy, mixed Ultic Hapludalfs
State of Pennsylvania
SSL-ProjectPSU201101   The Pennsylvania State University DataThe Pennsylvania State University
-Site ID478   Lat: 40° 05.00" north  Long: 76° 169.00" west  MLRA: 148Department of Crop and Soil Sciences
-Pedon No. 77PA071021452 ASI Building
-General Methods 1B1A, 2A1, 2BUniversity Park, PA 16802-3504

Andic Soil Properties Tier 1-1--2--3--4--5--6--7--8--9--10--11--12--13--14--15--16--17--18--19--20--21-
 
TotalFineCaCO3CoSi toEst.1-75Vol >2mmBulkCOLEAl+½FeAl+½Fe
ClayClayClayVCoSClayFraction% of(- - - - 1500 kPa - - - -)DensityWhole(- - - - - - - - - - Glass Content - - - - - - - - - -)*15.625*60.0
Depth<.002<.0002<.002.02 - 2ContentWhole Soilair-dryfield moist/Clay33 kPaSoilcsivfsfsmscsvcsWt Avg+Glass+Glass
Layer(cm)HorzPrep(- - - - - - - - - - - % of <2 mm - - - - - - - - -)% of <75 mm(- - - - - - - - % - - - - - - -)g cm-3cm cm-1(- - - - - - - - - - - - - - - - - - - - - % - - - - - - - - - - - - - - - - - - - - -)
3A1a1a3C2a1aDbWR1
 
PSU036980-13Ap1S19.789.00.461.38
PSU0369913-23Ap2S19.979.40.471.52
PSU0370023-41Bt1S25.1410.70.431.47
PSU0370141-56Bt2S23.81512.00.501.43
PSU0370256-79BC1S15.2128.20.541.41
PSU0370379-102BC2S6.7tr4.60.691.29
PSU03704102-147C1S4.5tr4.81.071.39
PSU03705147-180C2S2.7tr3.91.441.46
PSU03706180-216C3S1.626.94.311.31
PSU03707216-234C4S1.9tr3.51.841.48



Andic Soil Properties Tier 2-1--2--3--4--5--6--7--8--9--10--11--12--13--14--15--16--17--18--19-
 
CO3Al+8*SiOpticalKClNH4OACSum(- Base Sat -)
pHpHOrgTotasNZ½Fe8*Si2*Fe+2*FeDensityExtrSumBases+NH4OACSum ofMelanic(- Atterberg -)
DepthH2ONaFCCCaCO3P RetOxalOxalOxalOxalOxalAlBasesExtr AlpH 7.0CationsIndexLLPI
Layer(cm)HorzPrep(- - - - - - - - - - - - - - - - - - - - - - - % wt - - - - - - - - - - - - - - - - - -)cmol(+) kg-1(- meq 100g-1 -)(- - - - % - - - - -)( % <0.4mm )
8C1aNK
 
PSU036980-13Ap1S6.20.980.3
PSU0369913-23Ap2S6.21.110.4
PSU0370023-41Bt1S6.10.260.3
PSU0370141-56Bt2S5.60.290.6
PSU0370256-79BC1S5.30.181.7
PSU0370379-102BC2S5.20.171.7
PSU03704102-147C1S5.20.155.8
PSU03705147-180C2S5.40.102.0
PSU03706180-216C3S5.50.361.4
PSU03707216-234C4S5.70.110.4
NSSC SSL Report Creation