*** Andic Soil Properties Data ***
Pedon ID: 1968PA015014( Bradford, Pennsylvania )Print Date: Nov 21 2024 12:03PM

Sampled as on Jul 27, 1968:Volusia
Revised to correlated:Volusia ; Fine-loamy, mixed Aeric Fragiaquepts
State of Pennsylvania
SSL-ProjectPSU201101   The Pennsylvania State University DataThe Pennsylvania State University
-Site ID88   Lat: 41° 5443.00" north  Long: 76° 1811.00" west  MLRA: 140Department of Crop and Soil Sciences
-Pedon No. 68PA015014452 ASI Building
-General Methods 1B1A, 2A1, 2BUniversity Park, PA 16802-3504

Andic Soil Properties Tier 1-1--2--3--4--5--6--7--8--9--10--11--12--13--14--15--16--17--18--19--20--21-
 
TotalFineCaCO3CoSi toEst.1-75Vol >2mmBulkCOLEAl+½FeAl+½Fe
ClayClayClayVCoSClayFraction% of(- - - - 1500 kPa - - - -)DensityWhole(- - - - - - - - - - Glass Content - - - - - - - - - -)*15.625*60.0
Depth<.002<.0002<.002.02 - 2ContentWhole Soilair-dryfield moist/Clay33 kPaSoilcsivfsfsmscsvcsWt Avg+Glass+Glass
Layer(cm)HorzPrep(- - - - - - - - - - - % of <2 mm - - - - - - - - -)% of <75 mm(- - - - - - - - % - - - - - - -)g cm-3cm cm-1(- - - - - - - - - - - - - - - - - - - - - % - - - - - - - - - - - - - - - - - - - - -)
3A1a1a3C2a1aDbWR1
 
PSU006330-20ApS21.92311.80.541.32
PSU0063420-28E1S20.3317.90.391.56
PSU0063528-36E2S21.3328.80.411.54
PSU0063636-53Bgx1S26.62510.50.391.54
PSU0063753-74Bgx2S28.03810.50.381.67
PSU0063874-97Bgx3S27.53710.90.401.68
PSU0063997-127Bgx4S28.04011.10.401.76
PSU00640127-157Bx1S25.93811.70.451.76
PSU00641157-183CS26.43812.30.471.76

Andic Soil Properties Tier 2-1--2--3--4--5--6--7--8--9--10--11--12--13--14--15--16--17--18--19-
 
CO3Al+8*SiOpticalKClNH4OACSum(- Base Sat -)
pHpHOrgTotasNZ½Fe8*Si2*Fe+2*FeDensityExtrSumBases+NH4OACSum ofMelanic(- Atterberg -)
DepthH2ONaFCCCaCO3P RetOxalOxalOxalOxalOxalAlBasesExtr AlpH 7.0CationsIndexLLPI
Layer(cm)HorzPrep(- - - - - - - - - - - - - - - - - - - - - - - % wt - - - - - - - - - - - - - - - - - -)cmol(+) kg-1(- meq 100g-1 -)(- - - - % - - - - -)( % <0.4mm )
8C1aNK
 
PSU006330-20ApS6.91.990.1
PSU0063420-28E1S6.50.670.1
PSU0063528-36E2S6.70.350.1
PSU0063636-53Bgx1S5.30.241.0
PSU0063753-74Bgx2S4.80.092.2
PSU0063874-97Bgx3S5.00.091.0
PSU0063997-127Bgx4S6.20.100.1
PSU00640127-157Bx1S6.90.060.1
PSU00641157-183CS7.00.060.1


NSSC SSL Report Creation