*** Supplementary Characterization Data ***
Pedon ID: S1971UT039005( Sanpete, Utah )Print Date: Apr 28 2024 7:01AM

Sampled as on Jun 27, 1971:Tingey
Revised to correlated:unnamed ; Fine-loamy, mixed Argic Cryoborolls
United States Department of Agriculture
SSL-ProjectNL71UT005   SANPETENatural Resources Conservation Service
-Site IDS1971UT039005   National Soil Survey Center
-Pedon No. 71C0039Soil Survey Laboratory
-General Methods 1B1A, 2A1, 2BLincoln, Nebraska 68508-3866

Tier 1-1--2--3--4--5--6--7--8--9--10--11--12--13--14--15--16--17--18--19--20--21--22--23--24--25-
 
(- - - - - - - - - - - - - - - - - - - - - - Engineering PSDA - - - - - - - - - - - - - - - - - - - - -)(- - - - - Cumulative Curve Fractions - - - - -) (<75mm)( Atter- )( Gradation )
Percentage Passing SieveUSDA Less Than Diameters (mm) at bergUni-Cur-
Depth323/213/43/84104020020521..5.25.10.05605010LLPIfmtyvtur
Layer(cm)HorzPrep(-------------------Inches-------------------)(---------Number---------)(------Microns----)(---------Millimeter----------)(-----Percentile---)(----%----)CUCC
 
71C002500-5A1S1001001009999979490855932231788868266480.080.0530.001>1003.3
71C002515-22A2S10099989796938985826034262184838067480.080.0530.001>1002.3
71C0025222-60Bt1S10099989796959393896944352992908776580.050.030-->1000.2
71C0025366-90Bt21S10094898378777672705433262272716959450.110.0640.001>1002.1
71C0025490-125Bt22S10098969492908783816134272183827968500.070.0490.001>1002.0
71C00255125-170CS10096938885838077755632242077757363460.090.0600.001>1003.7

Tier 2-26--27--28--29--30--31--32--33--34--35--36--37--38--39--40--41--42--43--44--45--46--47--48--49--50-
 
(- - - - - - - - - - - - - - - - - - - - - - Weight Fractions - - - - - - - - - - - - - - - - - - - - -)(- - - - - - - - - - - Weight Per Unit Volume (g cm-3 )- - - - - - - -)(- - Void - -)
Whole Soil (mm)<75 mm FractionWhole Soil<2 mm FractionRatios
>225025075752057575205Soil SurEngineeringSoil SurveyEngineeringAt 33 kPa
Depth-UP-75-2-20-5-2<2-2-20-5-2<233OvenMoistSatur331500OvenMoistSaturWhole<2
Layer(cm)HorzPrep(------------------- % of Whole Soil ------------------)(--------- % of <75 mm ---------)kPa-dry-ated kPa kPa -dry -ated Soilmm
3B13B13B14A1f4A1h
 
71C002500-5A1S2921--81437110154901.291.361.421.801.071.101.131.221.671.051.48
71C002515-22A2S15----154748515474851.481.541.631.921.371.411.431.541.850.790.93
71C0025222-60Bt1S614513321tr39743tr932.052.122.172.281.491.571.601.711.930.290.78
71C0025366-90Bt21S68431213101232282224722.172.232.282.351.561.641.661.791.970.220.70
71C0025490-125Bt22S65451373223517854832.072.142.172.291.471.571.571.691.920.280.80
71C00255125-170CS745412852126231553772.202.262.292.371.481.581.591.731.920.200.79


*** Supplementary Characterization Data ***
Pedon ID: S1971UT039005( Sanpete, Utah )Print Date: Apr 28 2024 7:01AM
Sampled As:Tingey
USDA-NRCS-NSSC-Soil Survey Laboratory;Pedon No.  71C0039

Tier 3-51--52--53--54--55--56--57--58--59--60--61--62--63--64--65--66--67--68--69--70--71--72--73--74--75-
 
(- - - - - - - - - - - - - - - - - Volume Fractions - - - - - - - - - - - - - - - -)C(- - - - - - - Ratios To Clay - - - - - -)(- - Linear Extensiblity - -)(- - WRD - -)
Whole Soil (mm) At 33 kPa/N<2 mm FractionWhole Soil<2 mmWhole<2
>225025075752052-.05-LTPoresRatFineCEC1500LEP33 kPato %Soilmm
Depth-UP-75-2-20-5-2<2.05.002.002DF-ioClaySumNH4-kPa331500Oven1500Oven
Layer(cm)HorzPrep(----------------------------- % of Whole Soil ---------------------------)CatsOACH2OkPakPa-drykPa-dry(---in3/in3---)
8D14C1
 
71C002500-5A1S1410--412186161273813170.330.619.4700.80.90.020.02
71C002515-22A2S8----8242922015122915140.870.395.7401.11.00.030.04
71C0025222-60Bt1S473510221tr5311991112130.430.670.337.6400.61.80.030.06
71C0025366-90Bt21S55351010812451088711130.620.326.9500.61.70.030.08
71C0025490-125Bt22S503510522250119712100.630.348.5601.32.20.050.09
71C00255125-170CS614410742139975890.460.359.4101.02.20.040.11

Tier 4-76--77--78--79--80--81--82--83--84--85--86--87--88--89--90--91--92--93--94--95--96--97--98-
 
(- - - - - - - - - - - - - - - - - - - Weight Fractions - Clay Free - - - - - - - - - - - - - - - - - -)TextPSDA (mm)pHElect.Part-
(--------------- Whole Soil ---------------)(------------------- <2 mm Fraction -------------------)-ureSandSiltClayCaRes-Con--icle
>275202-.05-<(------------- Sands -------------)(--- Silts ---)Clby2-.05-<Cl2ist.ductDen-
Depth-20-2.05.002.002VCCMFVFCFayPSDA.05.002.002.01MohmsdS m-1sity
Layer(cm)HorzPrep(- % of >2 mm Sand and Silt -)(------------------% of Sand and Silt -------------)<2 mm(---- % of 2 mm ----)(-------- <2 mm --------)g cm-3
3A1a1a3A1a1a3A1a1a3A1a1a8C1e
 
71C002500-5A1S34983828162362225222123l46.334.719.06.7
71C002515-22A2S1919144635261252029222032l43.332.324.46.8
71C0025222-60Bt1S69311714142341728222346cl37.531.131.47.2
71C0025366-90Bt21S751431311111241829242243cl37.532.330.27.2
71C0025490-125Bt22S71841513101141829262135l39.434.925.77.2
71C00255125-170CS799311971251830242134l40.733.825.57.5
NSSC SSL Report Creation