*** Supplementary Characterization Data ***
Pedon ID: S2017CO013007A( Boulder, Colorado )Print Date: Dec 7 2025 10:13AM

Sampled as on May 24, 2017:Calkins ; Coarse-loamy, mixed, superactive, mesic Cumulic Haplustoll
Revised to :
United States Department of Agriculture
SSL-ProjectC2017USCO096   DSP 2017 CO Soil CarbonNatural Resources Conservation Service
-Site IDS2017CO013007A   Lat: 40° 7' 57.20" north  Long: 105° 8' 10.70" west  MLRA: 67BNational Soil Survey Center
-Pedon No. 17N0861Kellogg Soil Survey Laboratory
-General Methods 1B1A, 2A1, 2BLincoln, Nebraska 68508-3866

Tier 1-1--2--3--4--5--6--7--8--9--10--11--12--13--14--15--16--17--18--19--20--21--22--23--24--25-
 
(- - - - - - - - - - - - - - - - - - - - - - Engineering PSDA - - - - - - - - - - - - - - - - - - - - -)(- - - - - Cumulative Curve Fractions - - - - -) (<75mm)( Atter- )( Gradation )
Percentage Passing SieveUSDA Less Than Diameters (mm) at bergUni-Cur-
Depth323/213/43/84104020020521..5.25.10.05605010LLPIfmtyvtur
Layer(cm)HorzPrep(-------------------Inches-------------------)(---------Number---------)(------Microns----)(---------Millimeter----------)(-----Percentile---)(----%----)CUCC
 
17N042200-13Ap1S10010010010010010010096
17N0422113-38Ap2S10010010010010010010096
17N0422238-50Bw1S1001001001001001009995

Tier 2-26--27--28--29--30--31--32--33--34--35--36--37--38--39--40--41--42--43--44--45--46--47--48--49--50-
 
(- - - - - - - - - - - - - - - - - - - - - - Weight Fractions - - - - - - - - - - - - - - - - - - - - -)(- - - - - - - - - - - Weight Per Unit Volume (g cm-3 )- - - - - - - -)(- - Void - -)
Whole Soil (mm)<75 mm FractionWhole Soil<2 mm FractionRatios
>225025075752057575205Soil SurEngineeringSoil SurveyEngineeringAt 33 kPa
Depth-UP-75-2-20-5-2<2-2-20-5-2<233OvenMoistSatur331500OvenMoistSaturWhole<2
Layer(cm)HorzPrep(------------------- % of Whole Soil ------------------)(--------- % of <75 mm ---------)kPa-dry-ated kPa kPa -dry -ated Soilmm
 
17N042200-13Ap1S44--tr4964--tr4961.4811.923
17N0422113-38Ap2S44--tr4964--tr4961.4811.923
17N0422238-50Bw1S55--14955--14951.4811.923

1The whole-soil bulk density was not measured. It was calculated using 1.45 g/cc as the 1/3-bar bulk density of the less-than-2-mm fraction for mineral soils.
3The saturated whole-soil bulk density was not measured. It was calculated using 1.45 g/cc as the 1/3-bar bulk density of the less-than-2-mm fraction for mineral soils.
Tier 3-51--52--53--54--55--56--57--58--59--60--61--62--63--64--65--66--67--68--69--70--71--72--73--74--75-
 
(- - - - - - - - - - - - - - - - - Volume Fractions - - - - - - - - - - - - - - - -)C(- - - - - - - Ratios To Clay - - - - - -)(- - Linear Extensiblity - -)(- - WRD - -)
Whole Soil (mm) At 33 kPa/N<2 mm FractionWhole Soil<2 mmWhole<2
>225025075752052-.05-LTPoresRatFineCEC1500LEP33 kPato %Soilmm
Depth-UP-75-2-20-5-2<2.05.002.002DF-ioClaySumNH4-kPa331500Oven1500Oven
Layer(cm)HorzPrep(----------------------------- % of Whole Soil ---------------------------)CatsOACH2OkPakPa-drykPa-dry(---in3/in3---)
 
17N042200-13Ap1S2----2--tr298
17N042200-13Ap1N8
17N0422113-38Ap2S2----2--tr298
17N0422113-38Ap2N6
17N0422238-50Bw1S3----3--1297
17N0422238-50Bw1N7
NSSC SSL Report Creation